Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. Section R901 General R901.1 Scope The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. Flashing for asphalt shingles shall comply with this section. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. Same as Maximum Ultimate Design Wind Speed, Preservative-treated shakes and shingles of, Fire-retardant-treated shakes and shingles of, Preservative-treated tapersawn shakes of Southern pine treated in accordance with AWPA Standard U1 (Commodity Specification A, Special Requirement 4.6), Forest Products Laboratory of the Texas Forest Services, Preservative-treated tapersawn shakes of Southern Yellow Pine, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Chapter 9 also provides requirements for roof drainage, flashing, above-deck thermal insulation, rooftop-mounted photovoltaic systems and recovering or replacing an existing roof covering. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with, Flashing against a vertical front wall, as well as soil, A drip edge shall be provided at eaves and rake edges of shingle roofs. Roofing materials must be installed in accordance with Chapter 9 of the 2020 Minnesota Residential Code and the manufacturer's installation Stainless steel fasteners are acceptable for metal roofs. A liquid-applied protective coating that complies with Table R905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Part III Building Planning and Construction, R907 Rooftop-Mounted Photovoltaic Panel Systems, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T [RE] Solar-Ready ProvisionsDetached One- And Two-Family Dwellings and Townhouses, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections, Flashings shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet, Flashings shall be installed at wall and roof intersections, wherever there is a change in roof, A cricket or saddle shall be installed on the ridge side of any, The requirements set forth in this section shall apply to the application of, ASTM D6380 Class M mineral-surfaced roll roofing. hbbd```b``3@$R&5d}"uA$$X ,>,rLYfH 2o2dbO
C"=Vbz CHEX/#300 k
Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. The installation of sprayed polyurethane foam roofing shall comply with the provisions of this section. (R803.1) Spaced lumber sheathing for wood shingle and shake roofing shall conform to the requirements of sections R905.7 and R905.8. Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. Slate shingles shall be secured to the roof with two fasteners per slate. Nails shall be corrosion resistant and not less than 11 gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. Part III Building Planning and Construction, R907 Rooftop-Mounted Photovoltaic Panel Systems, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T [RE] Solar-Ready ProvisionsDetached One- And Two-Family Dwellings and Townhouses, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections, Flashings shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet, Flashings shall be installed at wall and roof intersections, wherever there is a change in roof, A cricket or saddle shall be installed on the ridge side of any, The requirements set forth in this section shall apply to the application of, ASTM D6380 Class M mineral-surfaced roll roofing. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Stainless steel fasteners are acceptable for metal roofs. Foam plastic materials and installation shall comply with. are not required for roofs sheathed with lumber having a nominal width of less than 3 feet Stainless steel fasteners are acceptable for metal roofs. In areas where there has been a history of ice forming along the eaves causing a backup of water as designated in. Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. Asphalt shingles shall be used only on roof. The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. 2018 International Residential Code (IRC) COPYRIGHT PREFACE EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE arrow_right CHAPTER 1 SCOPE AND ADMINISTRATION arrow_right CHAPTER 2 DEFINITIONS arrow_right CHAPTER 3 BUILDING PLANNING arrow_right CHAPTER 4 FOUNDATIONS arrow_right CHAPTER 5 FLOORS arrow_right CHAPTER 6 WALL CONSTRUCTION arrow_right Above-deck thermal insulation board shall comply with the standards in Table R906.2. Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. In areas where the average daily temperature in January is 25F (-4C) or less, Wood shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Asphalt shingles shall be tested in accordance with ASTM D7158. Self-adhering polymer-modified bitumen. Cap nail shank shall have a length sufficient to penetrate through the roof sheathing or not less than, The standard calculations contained in ASTM D7158 assume Exposure Category B or C and a. Install a nominal 4-inch-wide roof deck flashing tape over all roof sheathing panel seams and cover with #30 felt or equivalent synthetic underlayment. Asphalt shingle packaging shall bear a. Modified bitumen roofing shall comply with the standards in Table R905.11.2. Wood shakes shall comply with the requirements of Table R905.8.5. The installation of slate shingles shall comply with the provisions of this section. Materials and methods of application used for recovering or replacing an existing, The structural roof components shall be capable of supporting the, Flashings shall be reconstructed in accordance with, Chapter 9 addresses the design and construction of, R902.2 Fire-Retardant-Treated Shingles and Shakes, R902.3 Building-Integrated Photovoltaic Product, R902.4 Rooftop-Mounted Photovoltaic Panel Systems, R903.4.1 Secondary (Emergency Overflow) Drains or Scuppers, R904.3 Material Specifications and Physical Characteristics, Section R905 Requirements for Roof Coverings, In areas where the average daily temperature in January is 25F (-4C) Asphalt shingles shall be used only on roof. Asphalt shingle packaging shall bear a. Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. 3. Each bundle of shakes shall be identified by a, The installation of built-up roofs shall comply with the provisions of this section and the manufacturer's. CONTINUE WITH CODE REQ'S Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. Paint systems in accordance with ASTM A 755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A 792, ASTM A 875, ASTM A 463, or ASTM A 653. For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table R905.2.8.2. Same as Maximum Ultimate Design Wind Speed, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet. Each bundle of shakes shall be identified by a, The installation of built-up roofs shall comply with the provisions of this section and the manufacturer's. R905.2 Asphalt shingles. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. The bottom layer shall be 18 inches (457 mm) and the top layer not less than 36 inches (914 mm) wide. 12 oz/sq ft for preformed metal shingle systems. The installation of liquid-applied roofing shall comply with the provisions of this section. Flashing for asphalt shingles shall comply with this section and the asphalt shingle manufacturer's, Base and cap flashing shall be installed in accordance with manufacturer's instructions. R905.2.4.1 Wind Resistance of Asphalt Shingles, R905.14 Sprayed Polyurethane Foam Roofing, Section R907 Rooftop-Mounted Photovoltaic Systems, R907.1 Rooftop-Mounted Photovoltaic Systems, Section R909 Rooftop-Mounted Photovoltaic Panel Systems, Building-integrated photovoltaic products. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Interlayment shall comply with ASTM D226, Type I. Thermoset single-ply membrane roofs shall have a design. For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table R905.2.8.2. Wood shakes shall comply with the requirements of Table 905.8.5. R905.2.2 Slope. Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. Table R803.1 is for roof sheathing which requires 5/8 plywood with rafters 24" o.c. For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. The installation of wood shakes shall comply with the provisions of this section. For SI: 1 ounce per square foot = 0.305 kg/m, The installation of modified bitumen roofing shall comply with the provisions of this section and the manufacturer's, Modified bitumen roofing shall have a design. Install flashing at roof penetrations and wall intersections. Section R804 Cold-Formed Steel Roof Framing Section R806 Roof Ventilation Section R807 Attic Access Chapter 9 Roof Assemblies In areas where there has been a history of ice forming along the eaves causing a backup of water as designated in. conditions about your roof that may limit your product choices or affect the cost of your roofing job. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum, Asphalt shingles shall have the minimum number of fasteners required by the manufacturer's, Where required, ice barriers shall comply with, Flashing for asphalt shingles shall comply with this section and the asphalt shingle manufacturer's, Base and cap flashing shall be installed in accordance with manufacturer's instructions. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. For closed valleys (valley covered with shingles), valley lining of one ply of smooth roll roofing complying with ASTM D6380 and not less than 36 inches wide (914 mm) or valley lining as described in Item 1 or 2 shall be permitted. In areas where the average daily temperature in January is 25F (-4C) or less, Wood shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. Wood shingles shall be laid with a side lap not less than 1, Roof flashing shall be not less than No. Interlayment shall comply with ASTM D226, Type I. Asphalt shingles shall be tested in accordance with ASTM D7158. 3. The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs. Roof Sheathing Ring Shank nails have been added to Table R602.3(1) Fastening Schedule with the designation RSRS-01 (2-3/8" x 0.113") as an option for roof sheathing attachment. Asphalt shingles shall comply with ASTM D3462. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. Thermoplastic single-ply membrane roofs shall have a design. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum -inch-diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than inch (19.1 mm) into the roof sheathing. Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, ASTM D6162; D6163; D6164; D6222; D6223; D6298, As an alternative, self-adhering polymer-modified bitumen, As an alternative, a minimum 4-inch-wide (102 mm) strip of self-adhering polymer-modified bitumen membrane complying with ASTM D1970, installed in accordance with the, The cap nail shank shall be not less than 0.083 inch (2.11 mm) for ring shank cap nails and 0.091 inch (2.31 mm) for smooth shank cap nails. %%EOF
Interpretation #: CEB-2018-10-2005-IRC-R905.2.1 Building or Fire Safety Law Interpreted 675 IAC 14-4.3, the 2005 Indiana Residential Code. Mineral-surfaced roll roofing shall not be applied on roof. Asphalt shingles shall be used only on roof slopes of two units vertical in 12 units horizontal (2:12) or greater. Liquid-applied roofing shall have a design. For closed valleys (valley covered with shingles), valley lining of one ply of smooth roll roofing complying with ASTM D 6380 and not less than 36 inches wide (914 mm) or valley lining as described in Item 1 or 2 shall be permitted. Interlayment shall comply with ASTM D226, Type I. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Same as Maximum Ultimate Design Wind Speed, Apply in accordance with the manufacturer's, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B 370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet, ASTM B 209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum, Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, As an alternative, self-adhering polymer-modified bitumen, The standard calculations contained in ASTM D 7158 assume Exposure Category B or C and. Slate shingles shall be secured to the roof with two fasteners per slate. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions.
The installation of asphalt shingles shall comply with the provisions of this section. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. Allowable spans for lumber used as roof sheathing shall conform to Table R803.1. Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs. Liquid-applied roofing shall be installed in accordance with this chapter and the, Where required, an ice barrier shall comply with, In areas where there has been a history of ice forming along the eaves causing a backup of water, as designated in, The use of above-deck thermal insulation shall be permitted provided that such insulation is covered with an. Materials and methods of application used for re-covering or replacing an existing, The structural roof components shall be capable of supporting the, Roof replacement shall include the removal of existing layers of, Flashings shall be reconstructed in accordance with. R803.1 is for lumber sheathing. Same as Maximum Ultimate Design Wind Speed, Preservative-treated shakes and shingles of, Fire-retardant-treated shakes and shingles of, Preservative-treated tapersawn shakes of Southern pine treated in accordance with AWPA Standard U1 (Commodity Specification A, Special Requirement 4.6), Forest Products Laboratory of the Texas Forest Services, Preservative-treated tapersawn shakes of Southern Yellow Pine, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. Slate shingles shall be fastened to solidly sheathed roofs. Liquid-applied roofing shall be installed in accordance with this chapter and the manufacturer's instructions. Stainless steel fasteners are acceptable for metal roofs. Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Foam plastic materials and installation shall comply with. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. In areas where there has been a history of ice forming along the eaves causing a backup of water as designated in. The installation of wood shakes shall comply with the provisions of this section. Sprayed polyurethane foam roofs shall have a design. Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. About this chapter: Chapter 10 contains requirements for the construction, seismic reinforcing and anchorage of masonry chimneys and fireplaces; and establishes standards for the use and installation of factory-built chimneys, fireplaces and masonry heaters. Slate shingles shall comply with ASTM C406. Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. 26 gage [0.019 inch (0.5 mm)] corrosion-resistant sheet metal and shall extend not less than 11 inches (279 mm) from the centerline each way. Roof valley flashing shall be not less than No. A base sheet that complies with the requirements of. R803.1 Lumber sheathing. Slate shingles shall be fastened to solidly sheathed roofs. Valley flashing shall be not less than 15 inches (381 mm) wide. 2018, 2021 IECC: Mass walls shall be in accordance with Section R402.2.5 (N1102.2.5 in 2018 IRC). The installation of asphalt shingles shall comply with the provisions of this section. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. Where the existing roof covering is slate, clay, cement or asbestos-cement tile. The installation of wood shingles shall comply with the provisions of this section. Wood shingles shall be laid with a side lap not less than 1, NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES, Roof flashing shall be not less than No. Where exterior plaster or adhered masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and Section 703.6.3. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. Roof valley flashing shall be not less than No. Liquid-applied roofing shall be installed in accordance with this chapter and the. Above-deck thermal insulation board shall comply with the standards in Table R906.2. Section R901 General R901.1 Scope The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. Reroofing shall not be required to meet the minimum design, For roofs that provide positive drainage, recovering or replacing an existing, Complete and separate roofing systems, such as standing-seam metal roof systems, that are designed to transmit the roof loads directly to the building's structural system and do not rely on existing roofs and, Where the existing roof has two or more applications of any type of. Sprayed polyurethane foam roofs shall have a design. Asphalt shingles shall be used only on roof. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. Adjacent segments of drip edge shall be overlapped not less than 2 inches (51 mm). The GAF VersaShield Fire-Resistant Roof Deck Protection may be placed under or over the counterbattens. Self-adhering polymer modified bitumen. Each bundle of shakes shall be identified by a. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. The installation of wood shingles shall comply with the provisions of this section. Htt4 & -`P .+Yn0a|bZN4U+yX*iNFk $
A liquid-applied protective coating that complies with Table R905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, ASTM D6162; D6163; D6164; D6222; D6223; D6298, As an alternative, self-adhering polymer-modified bitumen, As an alternative, a minimum 4-inch-wide (102 mm) strip of self-adhering polymer-modified bitumen membrane complying with ASTM D1970, installed in accordance with the, The cap nail shank shall be not less than 0.083 inch (2.11 mm) for ring shank cap nails and 0.091 inch (2.31 mm) for smooth shank cap nails. Asphalt shingles shall comply with ASTM D3462. Foam plastic materials and installation shall comply with Section 316. The framing assembly incudes horizontal braces, vertical retrofit studs, and compression blocks. Wood shingles shall be laid with a side lap not less than 1, NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES, Roof flashing shall be not less than No. 12 oz/sq ft for preformed metal shingle systems. The installation of wood shakes shall comply with the provisions of this section. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. Modified bitumen membrane roofs shall have a design. Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. Liquid-applied roofing shall have a design. The installation of wood shingles shall comply with the provisions of this section. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum, Asphalt shingles shall have the minimum number of fasteners required by the manufacturer's. Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs. Asphalt shingles shall comply with ASTM D3462. For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D3909 or ASTM D6380 Class M, shall be permitted. Asphalt shingles shall be used only on roof. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. Slate shingles shall comply with ASTM C 406. Minimum headlap for slate shingles shall be in accordance with Table R905.6.5. the 2018 International Residential Code (IRC) simplified wall bracing requirements. Roof penetrations shall be flashed and sealed in accordance with this chapter. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions.